A Cost Effective Solution

With our barrier technology, current filtration equipment at FBO and fixed fueling sites with lower flow rate systems can easily adapt this alternative solution. Parker Velcon SAP-free barrier filtration provides drop-in replacement for our monitor cartridges used in models VF-61 (5") and VF-609 (6") housings and similar competitors housings.
  • Minimal changes to your current operational procedures
  • No modifications to the filter housing
Unit of Measure

Specifications

Brands

N/A Filtration Corp. of America

Fuel

N/A Avgas Jet

Cartridge Flow Rate

N/A 96 gpm

Element Model

N/A ACOX-524A

Features

Features

N/A
  • Water and dirt are prevented from passing downstream allowing only clean, dry fuel.
  • Drop in solution for existing housings without the need for costly retrofitting or addition of electronic sensors.
  • No SAP materials used in the manufacture of ACOX™ series of elements.
  • Effective against low-water emulsions and water slugs. Effective in fuel containing FSII anti-icing additive).
  • Meets the effluent fuel quality and structural requirements of EI-1588.

Additional Information

Additional Information

N/A A drop-in solution for current 5" & 6" diameter filter monitors including competitor brand VF-21SB/22SB and VFH-1 models.

Surface/Barrier Technology

Our new surface/barrier filter element is manufactured using a very fine hydrophobic material that prevents solids and water from passing through. There is absolutely no SAP used in this filter. Solids are held within the element while water is repelled by the hydrophobic material and falls to the bottom of the vessel.

With our ACOX™ element range, there is no need for expensive & costly retrofitting of filtration systems for smaller into-plane fueling applications. ACOX™ filter elements are a true direct drop-in replacement for the various filter housings. See Filter Element Selection below for basic cross-referencing:

Replace the cartridge when the differential pressure reaches 22 psid or after one year of service. Because of the limited sump space in the vessel, IT IS IMPERITIVE to drain the sump at EVERY FUELING. As an option, a water detection probe is available for installation, Parker Velcon part number 125-Q.

Note

Note

N/A Effective against dirt and water. Can be used with fuel containing FSII.

Optional differential pressure gauge assembly available: P/N 10678 for VF-61, VF-61E, VF-62

For further information or advice please contact your local Parker AFD distributor or Parker AFD.