Filtration Corporation of America
1118 Hill Avenue Glen Ellyn, IL 60137 Tel: 630.858.9030 Fax: 630.858.0953 Email:info@filtrationcorp.com Website: www.filtrationcorp.com
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves. Installed in the main flow line. the standard Model 108-2 acts as a back-pressure or pressure sustaining valve. In this configuration, the valve maintains a constant upstream pressure regardless of fluctuating downstream demand. When used in a bypass line, the same model will function as a relief valve, protecting the system against potentially damaging surges.
Relief: Maintains a constant inlet pressure by relieving excess high pressure.
Sustaining: Prevents pressure from dropping below a minimum.
Inlet pressure is accurate over a wide range of flow.
Inlet pressure is adjustable with a complete range of control springs.